73
13.10.6 – Outdoor reset
with room compensation
While in the “Installers’ Menu” (section
13.17) set the parameter to 02.
The system will function exactly as
described in the previous “Outdoor
reset adjustment” sections except
that now the boiler pump will stay on
permanently. The opening of the room
thermostat contacts will translate into
a parallel downward movement of
the curve in Figures 13-2 and 13-3.
The value by which the curve moves
downwards can be adjusted by the
parameter present in the
“Installers’ Menu”, see section 13.17.
The parameter can range
from 1 °F (1 °C) to 36 °F, (20°C). The
suggested values for this parameter
are:
- 18 °F (10°C) for high temperature
radiator systems;
- 6 °F (3°C) for low temperature radiant
panel systems
Values of this parameter that are
too high may translate into room
temperature instability. Values that are
too low may make the action of the
room thermostat ineffective.
Climatic adjustment with room
compensation can be used in all the
systems described in Section 13.10.1.
The advantage being that the constant
running of the pump will stabilize and
standardize the room temperatures.
This is especially true when some loops
in the heating system have considerably
greater volume than others.
13 - USE
OA = Slope of the line
Ob = Minimum heating
temperature
Oc = Maximum heating
temperature
br = “Fix point” of the angle
fulcrum of the line
b = parallel shift of the line
(adjusted by the heating
knob, item “7” of gure 13-1)
Figure 13-3 - Graphs of the outdoor reset adjustment
(in uence of parameter “b”)
Figure 13-2 - Graph of the outdoor reset adjustment
(in uence of parameters “br”, “OA”, “Ob” and “Oc”)
Outside temperature (°F)
Calculated temperature (°F)
Outside temperature (°F)
Calculated temperature (°F)
Seitenansicht 0
1 2 3 4 5 6 ... 35 36

Inhaltsverzeichnis

Seite 1 - 13 - USE

7313.10.6 – Outdoor reset with room compensationWhile in the “Installers’ Menu” (section 13.17) set the parameter to 02. The system will function ex

Seite 2 - CAUTION!!!

8213 - USEE1413.18.2 - Diagnostics: “E” blocking errors (continued)“E” CodeBlocking descriptionChecks to makeSolutionsU8 return temperature sensor sho

Seite 3

83Service and maintenance schedulesService Technician User maintenanceAnnual Startup:- Address reported problems (Follow section 14.1.1);- Check all p

Seite 4

8414.1.6 - Check ignition and fl ame sense electrodes1. Remove the fan-burner assembly unit (see section 14.3)2. Remove any deposits accumulated on the

Seite 5

85plumbing contractor or authorized inspection agency, to ensure that the product has not been affected by corrosive water conditions and to ensure th

Seite 6 - Diagnostics

8614 - MAINTENANCEFigure 14-1 Removing the casing 14.2 - Removing the casingIn order to remove the casing, follow the steps below while refering to Fi

Seite 7

87Figure 14-2 Remove the fan-burner assembly unit14 - MAINTENANCE6. prepare a suitable cover for the gas valve outlet under nut “D” so that no dirt, w

Seite 8

88A = Left ignition electrodeB = Right ignition electrodeC = Flame detection electrodeFigure 14-3 Positioning electrodes on burner (Use a hand caliper

Seite 9

8914 - MAINTENANCE14.6 - Condensate trap cleaningThe condensate trap must be checked every year and cleaned if required. Follow the steps below to pro

Seite 10

9014 - MAINTENANCE14.7 - Circulator pump motor replacement (only for 160-C model)To replace the circulator pump follow the steps below while, refering

Seite 11 - 14.1 - Care and

9114 - MAINTENANCE14.9 - 3-way valve removal (only for 160-C model)The 3-way valve, details “M” and “Q” in Figures 14-6 and 14-7, directs hot water pr

Seite 12

7413.12 - Delays, alarms and protective actionsTo protect the life of the appliance, improve comfort, and maximize energy savings, the following timin

Seite 13

9214 - MAINTENANCE14.10 - Draining the heating side of the boilerTo drain the heating side of the boiler follow the steps below: 1. cool boiler turnin

Seite 14 - 14.2 - Removing the

9314.13 - Water and fl ue temperature sensorThe boiler has a number of sensors that measure temperature. The electrical resistance between the sensor w

Seite 15 - fl ue gas side

9414.15 - Functional wiring diagramWARNING!!!Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dang

Seite 16

9514 - MAINTENANCE

Seite 17 - 14.6 - Condensate

9614.16 - Multiwire wiring diagramWARNING!!! Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dang

Seite 18

9714 - MAINTENANCE

Seite 19 - 160-C model)

98MODEL VSL-160-B; VSL-160-C;Country of destination USA and CanadaType of boiler Direct Vent and room

Seite 20 - WARNING!!!

9916 - SPARE PARTS

Seite 21

10016 - SPARE PARTS

Seite 23

7513.16 - “Users’ menu”When entering the “Users’ menu”, the display, item “1” in Figure 13-1, will start blinking indicating that a change of mode has

Seite 24 - 14.16 - Multiwire

10216 - SPARE PARTSSpare parts list1 - 81 9010 000 - CABLE UL IGNITOR CONN 90° L1552 - 81 9011 000 - NUT ZINC COATED 6MA3 - 81 9012 000 - SILICONE PIP

Seite 25

10338 - 81 9047 000 - 3/8G MALE to 1/8NPT FEMALE BUSHING39 - 81 9048 000 - GASKET EPDM D38 F20 SP640 - 81 9049 000 - 45xx WALL MOUNTING BRACKET41 - 81

Seite 26 - 15 - TECHNICAL DATA

10417 - READ OUT FLOW CHARTPush and hold the RESET key for a time, in seconds, indicated by the numberPush and release the RESET keyPush and hold toge

Seite 27 - 16 - SPARE PARTS

10517 - READ OUT FLOW CHARTCentral heatingAnti Freeze protectionLock-outBlocking errorD.H.W. active more than 120 min. Anti legionella protectionLast

Seite 28

106 may assume the follow values:61 - for boilers at NATURAL gas;62 - for boilers at LP gas; may assume the follow values:00 - 230Vac, 50Hz, °C;01 - 2

Seite 29

107NOTE62403559 R00 May 03, 2012

Seite 30 - Spare parts list

SLANT/FIN CORPORATION, Greenvale, N.Y. 11548 • Phone: (516) 484-2600FAX: (516) 484-5921 • Canada: Slant/Fin LTD/LTEE, Mississauga, Ontariowww.slantfin

Seite 31

7613 - USE13.17 - “Installer’s menu”CAUTION!!! Changing these parameters could cause the boiler and therefore the system to malfunction. For this rea

Seite 32 - 17 - READ OUT FLOW CHART

7713 - USEPARAMETER DESCRIPTION INFORMATION ON DISPLAY ITEM “2” OF FIGURE 13-1Can be changed (see Section 13.9): 00 = thermostatic adjus

Seite 33

7813.18 - DiagnosticsDuring the normal operation of the boiler, the display, of Figure 13-1, continually shows the operating status of the boiler as s

Seite 34

7913.18.1 - Diagnostics: “L” lock-outs“L”CodeLock-out descriptionChecks to makeSolutionsL01L02L03L0413 - USEL05L06L07L08L09L10L12L13L14L15L16No fl ame

Seite 35 - 62403559 R00 May 03, 2012

8013 - USE“L” CodeLock-out descriptionControlsSolutionsL18L19L20L25L32L33L45L46Program errorFlame sensed for 10 seconds, after the closure of the gas

Seite 36 - ©Slant/Fin Corp. 2013

8113 - USE13.18.2 - Diagnostics: “E” blocking errors“E” CodeBlocking descriptionChecks to makeSolutionsE01E02E04E07E08E11E12E13U1 boiler temperature s

Kommentare zu diesen Handbüchern

Keine Kommentare